1 |
Density kg/cum Cell Structure Colour |
JIS K 6767 |
30 ± 3 Kg/ M3 Closed cell Light Grey & also available In various customized colours |
2 |
Services Temperature Range |
Using Climate Chamber |
-40 to 115º C |
3 |
Ozone / UV & Weather / Chemical Resistance |
|
Good / Excellent |
4 |
Thermal Conductivity at 23/ 46 deg C |
IS 3346/1980 |
0.0315 /0.038 W/m ºk |
5 |
Thermal Conductivity at 40 deg C |
IS 3346/1980 |
0.035 W/m ºk |
6 |
Assessment of horizontal burning characteristics |
BS 4735 |
0.72 |
7 |
Fire Retardant Test A) Flammability Class-S4 B) Smoke density Class SR2 C) Dropping Class ST2 |
DIN-5510 (pt-2), 54837 |
Self extinguishing Passed Non Dripping |
8 |
Smoke density test |
ASTM D 2843-99 |
Passed |
9 |
Heavy metals for ROHS (Pollution) |
Directive 2002/95/EC |
Passed |
10 |
HCFC/ CFC |
US EPA 5021A(2014) |
Free/Not Detected |
11 |
Horizontal Flammability test for classifying materials 94 HBF. |
UL-94 |
Passed |
12 |
Horizontal Flammability test for classifying materials 94 HBF. |
UL-94 |
Passed |
13 |
Horizontal Flammability test for Paramount FR XPE |
IS 15061-02 |
Passed |
14 |
Fire Rating (Surface Spread of Flame- plain material) |
BS 476 Part 7 |
Class-1 |
15 |
Fire Rating (Fire Propagation Index) – laminated with aluminum foil |
BS 476 Part 6 |
Class-0 |
16 |
Oxygen Index |
ASTM D 2863 |
27.7 % |
17 |
Water Absorption |
JIS K 6767 -1976 |
0.01gm/cm2 |
18 |
Water Vapour Transmission Rate |
ASTM E-96 2016 |
0.040 gm/m2/Day |
19 |
Insulation without aluminum foil Water Vapour Permeability Water vapour resistance factor (µ) |
DIN EN ISO: 12572 |
Negligible 12805 (Plain-without foil) |
20 |
Insulation with aluminum foil on one side. Water Vapour Permeability Water vapour resistance factor (µ) |
DIN EN ISO: 12572 |
Negligible 17300 ( with AL foil) |
21 |
Thermal Stability |
BS 2972/1989 |
No visible signs of cracks and distortion. |
22 |
Overall Migration Test |
IS 9845-1998 |
Negligible effect of acids and alkalis |
23 |
Fungal Resistance Test |
ASTM G-21 |
Zero Rating (No growth observed) |
24 |
Bacteria Resistance Test |
ASTM G 22 |
No Bacteria growth observed |
25 |
Mold Growth |
IS 3144: 1992 |
No Mold growth observed |
26 |
Compression Set% (A) At 25% deflection (B) At 50% deflection |
JIS K 6767 |
24.7 % 42.1 % |
27 |
Dimensional Changes % (A) Machine direction (B) Cross direction |
JIS K 6767 |
(-)0.2 (-) 0.1 |
28 |
Tear Strength kg/cm2 (A) Machine direction (B) Cross direction |
JIS K 6767 |
1.6 1.4 |
29 |
Compressive Strength, KPa (A) Machine direction (B) Cross direction Elongation% |
ASTM D 3575 |
36.0 65.9 |
30 |
Tensile Strength kg/cm2 (A) Machine direction (B) Cross direction Elongation% (A) Machine direction (B) Cross direction |
JIS K 6767 |
2.4 2.2
113 100 |
31 |
90 deg peeling adhesion strength g/mm2 |
ISO 36 (2005) |
747 |
32 |
Toxicity Index |
NCD 1409 |
1.90 (Individual concentration of gases mostly either nil or well below the prescribed limit. |
33 |
Smoke Density |
ASTM D 2843-99 |
Passed |
34 |
Flammability |
NISO 3795 |
Passed |